OIL PRESSURE PROTECTION: Safety switch that protects refrigeration compressors from low lubricating oil pressure and stops the compressor if oil pressure fails.
FIXED 9 psi DIFFERENTIAL: Factory-set at 9.0 psi, no adjustment needed. Built-in thermal time relay with a fixed 120-second release time.
36 in CAPILLARY TUBE: 36 in (900 mm) capillary with a 1/4 in female flare nut pressure connection. Low-pressure side range: 29 inHg to 175 psi.
SPDT, 120/240 V AC OR DC: SPDT contacts for 120 or 240 V AC or DC control voltage. Manual reset. Rated for 245 psig maximum working pressure.
FOR HCFC AND HFC SYSTEMS: Suited to refrigeration systems using HCFC and non-flammable HFC refrigerants. UL listed for the USA and Canada. Verify your model before ordering.
Weight : 1.94 LBR
Model : 060B205391
UPC-EAN : 5702424499525
OIL PRESSURE PROTECTION: Safety switch that protects refrigeration compressors from low lubricating oil pressure and stops the compressor if oil pressure fails.
FIXED 9 psi DIFFERENTIAL: Factory-set at 9.0 psi, no adjustment needed. Built-in thermal time relay with a fixed 120-second release time.
36 in CAPILLARY TUBE: 36 in (900 mm) capillary with a 1/4 in female flare nut pressure connection. Low-pressure side range: 29 inHg to 175 psi.
SPDT, 120/240 V AC OR DC: SPDT contacts for 120 or 240 V AC or DC control voltage. Manual reset. Rated for 245 psig maximum working pressure.
FOR HCFC AND HFC SYSTEMS: Suited to refrigeration systems using HCFC and non-flammable HFC refrigerants. UL listed for the USA and Canada. Verify your model before ordering.
Weight : 1.94 LBR
Model : 060B205391
UPC-EAN : 5702424499525
Specifications
- Model: 060B205391 (type MP 54)
- Type: Oil differential pressure switch (lube oil protection control)
- Fixed differential: 9.0 psi
- Contact differential: 0.2 bar (2.9 psi)
- Time relay release: 120 s, fixed
- Low-pressure side range: 29 inHg to 175 psi
- Max working pressure: 245 psig (17 bar)
- Test pressure: 319 psig (22 bar)
- Contact function: SPDT
- Control voltage: 120 or 240 V AC or DC
- Pressure connection: 1/4 in female flare nut (DIN 8912)
- Capillary tube: 36 in (900 mm)
- Enclosure / reset: IP20 / manual
- Refrigerants: HCFC and non-flammable HFC
- Approvals: UL 873 (file E31024), CE, CSA C22.2, RoHS
Typical use: lubrication safety cutout on refrigeration compressors using HCFC and non-flammable HFC refrigerants. Confirm the model and your electrical supply before ordering.
G060B205391
New
Data sheet
- Product Feature
- 36 in CAPILLARY TUBE: 36 in (900 mm) capillary with a 1/4 in female flare nut pressure connection. Low-pressure side range: 29 inHg to 175 psi.
- FIXED 9 psi DIFFERENTIAL: Factory-set at 9.0 psi, no adjustment needed. Built-in thermal time relay with a fixed 120-second release time.
- FOR HCFC AND HFC SYSTEMS: Suited to refrigeration systems using HCFC and non-flammable HFC refrigerants. UL listed for the USA and Canada. Verify your model before ordering.
- OIL PRESSURE PROTECTION: Safety switch that protects refrigeration compressors from low lubricating oil pressure and stops the compressor if oil pressure fails.
- SPDT, 120/240 V AC OR DC: SPDT contacts for 120 or 240 V AC or DC control voltage. Manual reset. Rated for 245 psig maximum working pressure.
- Weight
- 1.94 LBR
- Model
- 060B205391
- UPC-EAN
- 5702424499525
No customer reviews for the moment.
You need to be logged in or create an account to give your appreciation of a review.